51edc551-11d6-4a5c-8555-453b94d5e87eTorch applied installation of APP-modified bitumen (asphalt) roofing membrane - ARMA (A5)Torch applied installation process of APP-modified bitumen roofing membranes (1 m2)Industry average, multiple producers9.8 kg/m2 total weight of cap sheet, base sheet, and ancillary materialstorched; atactic-polypropylene; mod bit; MB; modifieds; rubber roofAtactic-polypropylene (APP)-modified bitumen (asphalt) roofing base sheet - ARMA (A1-A3)Atactic-polypropylene (APP)-modified bitumen (asphalt) roofing cap sheet - ARMA (A1-A3)Materials productionOther materialsThis dataset represents the torch applied installation of the APP cap sheet and base sheet and should be used in combination with those datasets.
It contains the results for the module A5 according to EN 15804 and the PCR: Asphalt Shingles, Built-up Asphalt
Membrane Roofing and Modified Bituminous Membrane Roofing. It includes the installation into the building during the construction of the building, including both the provision of all materials, products and energy as well as the complete treatment of waste or residual waste at the building stage. This information module also contains effects and aspects that are associated with losses at the building stage (e.g. waste treatment and disposal of waste and material losses as well as the transport thereof).
A comparison with other products is only allowed by a similar application in the building. In principle, a comparison or evaluation of EPD data is only possible if all the datasets are created to be compared to EN 15804 and the product-specific features are considered.0The dataset represents the typical (based on expert input) installation of the low-slope APP-modified bitumen roofing membrane in the United States and/or Canada.Foreground system:
APP systems are most commonly installed using a propane torch. The roll is positioned and heated with the torch, causing the asphalt compound on the roll to melt and the parting film to burn off. The sheet is then slowly unrolled into liquid bitumen as the installer continues to heat the roll. A weighted roller follows the sheet to secure the seam. This process is used to install the base sheet and the cap sheet. Mineral granules are applied to the adhesive that has migrated out of the cap sheet seams to protect it from UV and for aesthetic reasons.
Background system:
Electricity: Electricity is modelled according to the individual country-specific situations. The country-specific modelling is achieved on multiple levels. Firstly, individual energy carrier specific power plants and plants for renewable energy sources are modelled according to the current national electricity grid mix. Modelling the electricity consumption mix includes transmission / distribution losses and the own use by energy producers (own consumption of power plants and "other" own consumption e.g. due to pumped storage hydro power etc.), as well as imported electricity. Secondly, the national emission and efficiency standards of the power plants are modelled as well as the share of electricity plants and combined heat and power plants (CHP). Thirdly, the country-specific energy carrier supply (share of imports and / or domestic supply) including the country-specific energy carrier properties (e.g. element and energy content) are accounted for. Fourthly, the exploration, mining/production, processing and transport processes of the energy carrier supply chains are modelled according to the specific situation of each electricity producing country. The different production and processing techniques (emissions and efficiencies) in the different energy producing countries are considered, e.g. different crude oil production technologies or different flaring rates at the oil platforms.
Thermal energy, process steam: The thermal energy and process steam supply is modelled according to the individual country-specific situation with regard to emission standards and considered energy carriers. The thermal energy and process steam are produced at heat plants. Efficiencies for thermal energy production are by definition 100% in relation to the corresponding energy carrier input. For process steam the efficiency ranges from 85%, 90% to 95%. The energy carriers used for the generation of thermal energy and process steam are modelled according to the specific import situation (see electricity above).
Transports: All relevant and known transport processes are included. Ocean-going and inland ship transport as well as rail, truck and pipeline transport of bulk commodities are considered.
Energy carriers: The energy carriers are modelled according to the specific supply situation (see electricity above).
Refinery products: Diesel fuel, gasoline, technical gases, fuel oils, lubricants and residues such as bitumen are modelled with a parameterised country-specific refinery model. The refinery model represents the current national standard in refining techniques (e.g. emission level, internal energy consumption, etc.) as well as the individual country-specific product output spectrum, which can be quite different from country to country. The supply of crude oil is modelled, again, according to the country-specific situation with the respective properties of the resources.Low-slope roofing systems are installed on roofs with slopes less than 2:12. Low-slope roofing systems are primarily used to protect buildings and structures from the weather. Modified bitumen roof systems are trusted to protect against weather conditions, temperature extremes, impacts and foot traffic. Multiple layers of roofing materials including engineered reinforcements provide strength and durability. It is a versatile solution, able to adapt to many roof designs.Partly terminated systemAttributionalNoneAllocation - market valueAllocation - net calorific valueAllocation - exergetic contentAllocation - massForeground system:
All packaging waste generated during installation, as well as 40% of the wooden pallets used for shipping of products, are assumed to be sent to landfill and the system credited with any avoided production of electricity generated from the combustion of landfill gas.
Background system: For the combined heat and power production, allocation by exergetic content is applied. For the electricity generation and by-products, e.g. gypsum, allocation by market value is applied due to no common physical properties. Within the refinery allocation by net calorific value and mass is used. For the combined crude oil, natural gas and natural gas liquids production allocation by net calorific value is applied.
For details please see the document "GaBi Databases Modelling Principles"Foreground system: none
Background system: All data used in the calculation of the LCI results refer to net calorific value.NoneGaBi Modelling PrinciplesGaBi Water Modelling PrinciplesCut-off rules for each unit process: Coverage of at least 95 % of mass and energy of the input and output flows, and 98 % of their environmental relevance (according to expert judgement).
For further details please see the document "GaBi Databases Modelling Principles"NoneLCI modelling is fully consistent. For details please see the document "GaBi Databases Modelling Principles"
Primary data was not collected for this installation dataset (excepting the weight of the base and cap sheets used). Rather, expert judgment and research were used in development.NoneFor details please see the document "GaBi Databases Modelling Principles"NoneGaBi databases75.0Not applicable2013-2014NoneA5: The environmental profile includes expenses for the construction process stage. A5 is installation into the building.
This dataset on installation should be used in combination with the APP cap and base sheet datasets. The EoL scenario used for the EPDs assumes 100% landfill.No statementPrimary energy from non renewable resources (gross cal. value)Primary energy from non renewable resources (net cal. value)Primary energy from renewable resources (gross cal. value)Primary energy from renewable resources (net cal. value)Primary energy demand from ren. and non ren. resources (net cal. value)Primary energy demand from ren. and non ren. resources (gross cal. value)TRACI 2.1, Ecotoxicity (recommended)TRACI 2.1, Human toxicity, cancer (recommended)TRACI 2.1, Human toxicity, non-canc. (recommended)TRACI 2.1, Global Warming Air, excl. biogenic carbonTRACI 2.1, Resources, Fossil fuelsTRACI 2.1, Human Health Particulate AirUSEtox, Ecotoxicity (recommended)USEtox, Human toxicity, cancer (recommended)TRACI 2.1, Ozone Depletion AirTRACI 2.1, Smog AirUSEtox, Human toxicity, non-canc. (recommended)Total freshwater consumption (including rainwater)Blue water consumptionBlue water useTotal freshwater useReCiPe 1.08 Endpoint (H) - Agricultural land occupationReCiPe 1.08 Endpoint (H) - Climate change Ecosystems, default, excl biogenic carbonReCiPe 1.08 Endpoint (H) - Climate change Human Health, default, excl biogenic carbonReCiPe 1.08 Endpoint (H) - Fossil depletionReCiPe 1.08 Endpoint (H) - Freshwater ecotoxicityReCiPe 1.08 Endpoint (H) - Freshwater eutrophicationReCiPe 1.08 Endpoint (H) - Human toxicityReCiPe 1.08 Endpoint (H) - Ionising radiationReCiPe 1.08 Endpoint (H) - Marine ecotoxicityReCiPe 1.08 Endpoint (H) - Metal depletionReCiPe 1.08 Endpoint (I) - Natural land transformationReCiPe 1.08 Endpoint (H) - Ozone depletionReCiPe 1.08 Endpoint (H) - Particulate matter formationReCiPe 1.08 Endpoint (H) - Photochemical oxidant formationReCiPe 1.08 Endpoint (H) - Terrestrial acidificationReCiPe 1.08 Endpoint (H) - Terrestrial ecotoxicityReCiPe 1.08 Endpoint (H) - Urban land occupationReCiPe 1.08 Midpoint (H) - Agricultural land occupationReCiPe 1.08 Midpoint (H) - Climate change, default, excl biogenic carbonReCiPe 1.08 Midpoint (H) - Fossil depletionReCiPe 1.08 Midpoint (H) - Freshwater ecotoxicityReCiPe 1.08 Midpoint (H) - Freshwater eutrophicationReCiPe 1.08 Midpoint (H) - Human toxicityReCiPe 1.08 Midpoint (H) - Ionising radiationReCiPe 1.08 Midpoint (H) - Marine ecotoxicityReCiPe 1.08 Midpoint (H) - Marine eutrophicationReCiPe 1.08 Midpoint (H) - Metal depletionReCiPe 1.08 Midpoint (H) - Natural land transformationReCiPe 1.08 Midpoint (I) - Ozone depletionReCiPe 1.08 Midpoint (H) - Particulate matter formationReCiPe 1.08 Midpoint (H) - Photochemical oxidant formationReCiPe 1.08 Midpoint (H) - Terrestrial acidificationReCiPe 1.08 Midpoint (H) - Terrestrial ecotoxicityReCiPe 1.08 Midpoint (H) - Urban land occupationReCiPe 1.08 Midpoint (H) - Water depletionReCiPe 1.08 Midpoint (I) - Climate change, default, excl biogenic carbonReCiPe 1.08 Midpoint (E) - Climate change, default, excl biogenic carbonReCiPe 1.08 Endpoint (I) - Climate change Ecosystems, default, excl biogenic carbonReCiPe 1.08 Endpoint (I) - Climate change Human Health, default, excl biogenic carbonReCiPe 1.08 Endpoint (E) - Climate change Ecosystems, default, excl biogenic carbonReCiPe 1.08 Endpoint (E) - Climate change Human Health, default, excl biogenic carbonReCiPe 1.08 Endpoint (I) - Freshwater eutrophicationReCiPe 1.08 Midpoint (I) - Freshwater eutrophicationReCiPe 1.08 Endpoint (E) - Freshwater eutrophicationReCiPe 1.08 Midpoint (E) - Freshwater eutrophicationReCiPe 1.08 Midpoint (E) - Marine eutrophicationReCiPe 1.08 Midpoint (I) - Marine eutrophicationReCiPe 1.08 Endpoint (I) - Ozone depletionReCiPe 1.08 Midpoint (H) - Ozone depletionReCiPe 1.08 Endpoint (E) - Ozone depletionReCiPe 1.08 Midpoint (E) - Ozone depletionReCiPe 1.08 Endpoint (I) - Terrestrial acidificationReCiPe 1.08 Midpoint (I) - Terrestrial acidificationReCiPe 1.08 Endpoint (E) - Terrestrial acidificationReCiPe 1.08 Midpoint (E) - Terrestrial acidificationReCiPe 1.08 Endpoint (I) - Photochemical oxidant formationReCiPe 1.08 Midpoint (I) - Photochemical oxidant formationReCiPe 1.08 Endpoint (E) - Photochemical oxidant formationReCiPe 1.08 Midpoint (E) - Photochemical oxidant formationReCiPe 1.08 Endpoint (I) - Particulate matter formationReCiPe 1.08 Midpoint (I) - Particulate matter formationReCiPe 1.08 Endpoint (E) - Particulate matter formationReCiPe 1.08 Midpoint (E) - Particulate matter formationReCiPe 1.08 Endpoint (I) - Ionising radiationReCiPe 1.08 Midpoint (I) - Ionising radiationReCiPe 1.08 Endpoint (E) - Ionising radiationReCiPe 1.08 Midpoint (E) - Ionising radiationReCiPe 1.08 Endpoint (I) - Agricultural land occupationReCiPe 1.08 Endpoint (I) - Urban land occupationReCiPe 1.08 Midpoint (I) - Agricultural land occupationReCiPe 1.08 Midpoint (I) - Urban land occupationReCiPe 1.08 Endpoint (E) - Agricultural land occupationReCiPe 1.08 Endpoint (E) - Urban land occupationReCiPe 1.08 Midpoint (E) - Agricultural land occupationReCiPe 1.08 Midpoint (E) - Urban land occupationReCiPe 1.08 Endpoint (H) - Natural land transformationReCiPe 1.08 Midpoint (I) - Natural land transformationReCiPe 1.08 Endpoint (E) - Natural land transformationReCiPe 1.08 Midpoint (E) - Natural land transformationReCiPe 1.08 Endpoint (I) - Fossil depletionReCiPe 1.08 Midpoint (E) - Fossil depletionReCiPe 1.08 Endpoint (E) - Fossil depletionReCiPe 1.08 Midpoint (I) - Fossil depletionReCiPe 1.08 Endpoint (I) - Metal depletionReCiPe 1.08 Midpoint (I) - Metal depletionReCiPe 1.08 Endpoint (E) - Metal depletionReCiPe 1.08 Midpoint (E) - Metal depletionReCiPe 1.08 Midpoint (E) - Water depletionReCiPe 1.08 Midpoint (I) - Water depletionReCiPe 1.08 Endpoint (I) - Freshwater ecotoxicityReCiPe 1.08 Endpoint (I) - Human toxicityReCiPe 1.08 Endpoint (I) - Marine ecotoxicityReCiPe 1.08 Endpoint (I) - Terrestrial ecotoxicityReCiPe 1.08 Midpoint (I) - Freshwater ecotoxicityReCiPe 1.08 Midpoint (I) - Human toxicityReCiPe 1.08 Midpoint (I) - Marine ecotoxicityReCiPe 1.08 Midpoint (I) - Terrestrial ecotoxicityReCiPe 1.08 Midpoint (E) - Terrestrial ecotoxicityReCiPe 1.08 Midpoint (E) - Marine ecotoxicityReCiPe 1.08 Midpoint (E) - Human toxicityReCiPe 1.08 Midpoint (E) - Freshwater ecotoxicityReCiPe 1.08 Endpoint (E) - Terrestrial ecotoxicityReCiPe 1.08 Endpoint (E) - Marine ecotoxicityReCiPe 1.08 Endpoint (E) - Human toxicityReCiPe 1.08 Endpoint (E) - Freshwater ecotoxicityAnthropogenic Abiotic Depletion Potential (AADP), TU BerlinReCiPe 1.08 Midpoint (H) - Climate change, incl biogenic carbonReCiPe 1.08 Endpoint (H) - Climate change Ecosystems, incl biogenic carbonReCiPe 1.08 Endpoint (H) - Climate change Human Health, incl biogenic carbonReCiPe 1.08 Endpoint (E) - Climate change Ecosystems, incl biogenic carbonReCiPe 1.08 Endpoint (E) - Climate change Human Health, incl biogenic carbonReCiPe 1.08 Midpoint (E) - Climate change, incl biogenic carbonReCiPe 1.08 Endpoint (I) - Climate change Ecosystems, incl biogenic carbonReCiPe 1.08 Endpoint (I) - Climate change Human Health, incl biogenic carbonReCiPe 1.08 Midpoint (I) - Climate change, incl biogenic carbonTRACI 2.1, Global Warming Air, incl. biogenic carbonTRACI 2.1, AcidificationTRACI 2.1, EutrophicationUBP 2013, Global warmingUBP 2013, Pesticides into soilUBP 2013, Radioactive waste to depositUBP 2013, Radioactive substances into airUBP 2013, Water resourcesUBP 2013, Energy resourcesUBP 2013, Water pollutantsUBP 2013, Heavy metals into soilUBP 2013, Mineral resourcesUBP 2013, POP into waterUBP 2013, Radioactive substances into waterUBP 2013, Carcinogenic substances into airUBP 2013, Heavy metals into airUBP 2013, Land useUBP 2013, Heavy metals into waterUBP 2013, Main air pollutantsUBP 2013, Ozone layer depletionUBP 2013, Non radioactive waste to depositGaBi conformity systemFully compliantFully compliantFully compliantFully compliantFully compliantNot definedThis background LCI data set can be used for any types of LCA studies.2020-01-01T00:00:00.000ILCD format 1.1thinkstepNo official approval by producer or operator2020-01-01T00:00:00.00000.00.001Data set finalised; entirely publishedGaBi databasesthinksteptrueOtherThe EPD owner (source code, database including extension modules and single data sets, documentation) remains property of thinkstep AG. thinkstep AG delivers GaBi licenses comprising data storage medium and manual as ordered by the customer. The license guarantees the right of use for one installation of GaBi. Further installations using the same license are not permitted. Additional licenses are only valid if the licensee holds at least one main license. Licenses are not transferable and must only be used within the licensee's organisation. Data sets may be copied for internal use. The number of copies is restricted to the number of licenses of the software system GaBi the licensee owns. The right of use is exclusively valid for the licensee. All rights reserved.APP-modified bitumen (asphalt) installed roofing membrane (torched)Output9.772875158123929.772875158123920Mixed primary / secondaryUnknown derivationvaluable